Fracture and Structural Integrity e-ISSN 1971-8993 Open access
Analytical, computational and physical models Vol. 19, No. 71 (2025)

Integrated FEM-Multibody Co-Simulation of Additively Manufactured Hip Prosthesis containing cracks.

Author and affiliation details
  • Domenico Gentile Corresponding author University of Molise, Italy ORCID iD0000-0002-2204-9345 domenico.gentile@unimol.it
  • Roberto Di Bona University of Molise, Italy ORCID iD0009-0005-9238-130X
  • Giuseppe Peter Vanoli University of Molise, Italy
  • Gabriel testa University of Cassino and Southern Lazio, Italy
  • Sara Ricci University of Cassino and Southern Lazio, Italy
DOI
10.3221/IGF-ESIS.71.09
Pages
108-123
Published
Licence
CC BY 4.0

Abstract

The increase in life expectancy and attention to the quality of life of elderly people spurred the need, in the last decades, to increase the capabilities of medical and surgical techniques. Among these, the development of prosthetic implants has been a staple of biomedical engineering research since the 70’s. In order to satisfy the challenging demands, the latest novelties in industrial engineering are being tested in their applicability to subjects. The 3D printing of metal alloys can produce a highly customizable product, which, after the proper heat treatments, can possess adequate mechanical properties to ensure a satisfactory component life. Defective products are often the results of wrong or absent post-processing treatments which may cause an uncontrolled crack propagation and a premature total failure of the implant. The behavior of such a product, with various critical crack conditions, was investigated by an integrated MBD-FEM co-simulation environment, focused on a femur subjected to total hip replacement. It was concluded that the Stress Intensity Factor (SIF) computed by the model is compatible with the premature failures experienced by patients, and as such, this model opens the possibility for further analyses aimed at understanding the role of defects on the durability of prothesis

Keywords

Article history

  1. ReceivedUntil the next stage: 24 days
  2. RevisedUntil the next stage: 8 days
  3. AcceptedUntil the next stage: 3 days
  4. Published

How to cite

APA

Gentile, D., Di Bona, R., Vanoli, G. P., testa, G., & Ricci, S. (2024). Integrated FEM-Multibody Co-Simulation of Additively Manufactured Hip Prosthesis containing cracks. Fracture and Structural Integrity, 19(71), 108–123. https://doi.org/10.3221/IGF-ESIS.71.09

IEEE

D. Gentile, R. Di Bona, G. P. Vanoli, G. testa, and S. Ricci, “Integrated FEM-Multibody Co-Simulation of Additively Manufactured Hip Prosthesis containing cracks.,” Fracture and Structural Integrity, vol. 19, no. 71, pp. 108–123, 2024, doi: 10.3221/IGF-ESIS.71.09.

MLA

Gentile, Domenico, et al. “Integrated FEM-Multibody Co-Simulation of Additively Manufactured Hip Prosthesis containing cracks.” Fracture and Structural Integrity, vol. 19, no. 71, 2024, pp. 108–123. https://doi.org/10.3221/IGF-ESIS.71.09.

Chicago

Gentile, Domenico, Roberto Di Bona, Giuseppe Peter Vanoli, Gabriel testa, and Sara Ricci. 2024. “Integrated FEM-Multibody Co-Simulation of Additively Manufactured Hip Prosthesis containing cracks.” Fracture and Structural Integrity 19 (71): 108–123. https://doi.org/10.3221/IGF-ESIS.71.09.

Harvard

Gentile, D., Di Bona, R., Vanoli, G.P., testa, G. and Ricci, S. (2024) ‘Integrated FEM-Multibody Co-Simulation of Additively Manufactured Hip Prosthesis containing cracks.’, Fracture and Structural Integrity, 19(71), pp. 108–123. doi: 10.3221/IGF-ESIS.71.09.

Vancouver

Gentile D, Di Bona R, Vanoli GP, testa G, Ricci S. Integrated FEM-Multibody Co-Simulation of Additively Manufactured Hip Prosthesis containing cracks. Fracture and Structural Integrity. 2024;19(71):108-123. doi:10.3221/IGF-ESIS.71.09

BibTeX

@article{gentile2024, author = {Gentile, Domenico and Di Bona, Roberto and Vanoli, Giuseppe Peter and testa, Gabriel and Ricci, Sara}, title = {Integrated FEM-Multibody Co-Simulation of Additively Manufactured Hip Prosthesis containing cracks.}, journal = {Fracture and Structural Integrity}, year = {2024}, volume = {19}, number = {71}, pages = {108--123}, doi = {10.3221/IGF-ESIS.71.09}, url = {https://doi.org/10.3221/IGF-ESIS.71.09}, issn = {1971-8993} }

RIS

TY - JOUR AU - Gentile, Domenico AU - Di Bona, Roberto AU - Vanoli, Giuseppe Peter AU - testa, Gabriel AU - Ricci, Sara TI - Integrated FEM-Multibody Co-Simulation of Additively Manufactured Hip Prosthesis containing cracks. JO - Fracture and Structural Integrity T2 - Fracture and Structural Integrity PY - 2024 DA - 2024/10/14 VL - 19 IS - 71 SP - 108 EP - 123 DO - 10.3221/IGF-ESIS.71.09 UR - https://doi.org/10.3221/IGF-ESIS.71.09 SN - 1971-8993 ER -

Licence

Creative Commons Attribution 4.0 International

May be shared and adapted, provided appropriate credit is given. Copyright © 2024 Domenico Gentile, Roberto Di Bona, Giuseppe Peter Vanoli, Gabriel testa, Sara Ricci.

Copyright 
Authors are allowed to retain both the copyright and the publishing rights of their articles without restrictions.  

Open Access Statement

Fracture and Structural Integrity (F&SI) is an open-access journal which means that all content is freely available without charge to the user or his/her institution. Users are allowed to read, download, copy, distribute, print, search, or link to the full texts of the articles in this journal without asking prior permission from the publisher or the author. This is in accordance with the DOAI definition of open access.

F&SI operates under the Creative Commons Licence Attribution 4.0 International (CC-BY 4.0). This allows to copy and redistribute the material in any medium or format, to remix, transform and build upon the material for any purpose, even commercially, but giving appropriate credit, providing a link to the license, and indicating if changes were made.