Fracture and Structural Integrity e-ISSN 1971-8993 Open access
Miscellanea Vol. 7, No. 26 (2013)

Coupled FEM-DBEM method to assess crack growth in magnet system of Wendelstein 7-X

Author and affiliation details
  • R. Citarella Corresponding author iacoviello@unicas.it
  • M. Lepore
  • Joris Fellinger
  • Victor Bykov
  • Felix Schauer
DOI
10.3221/IGF-ESIS.26.10
Pages
Pages 92-103
Published

Abstract

The fivefold symmetric modular stellarator Wendelstein 7-X (W7-X) is currently under construction in Greifswald, Germany. The superconducting coils of the magnet system are bolted onto a central support ring and interconnected with five so-called lateral support elements (LSEs) per half module. After welding of the LSE hollow boxes to the coil cases, cracks were found in the vicinity of the welds that could potentially limit the allowed number N of electromagnetic (EM) load cycles of the machine. In response to the appearance of first cracks during assembly, the Stress Intensity Factors (SIFs) were calculated and corresponding crack growth rates of theoretical semi-circular cracks of measured sizes in potentially critical position and orientation were predicted using Paris’ law, whose parameters were calibrated in fatigue tests at cryogenic temperature. In this paper the Dual Boundary Element Method (DBEM) is applied in a coupled FEM-DBEM approach to analyze the propagation of multiple cracks with different shapes. For this purpose, the crack path is assessed with the Minimum Strain Energy density criterion and SIFs are calculated by the Jintegral approach. The Finite Element Method (FEM) is adopted to model, using the commercial codes Ansys or Abaqus;, the overall component whereas the submodel analysis, in the volume surrounding the cracked area, is performed by FEM (“FEM-FEM approach”) or alternatively by DBEM (“FEM-DBEM approach”). The “FEM-FEM approach” considers a FEM submodel, that is extracted from the FEM global model; the latter provide the boundary conditions for the submodel. Such approach is affected by some restrictions in the crack propagation phase, whereas, with the “FEM-DBEM approach”, the crack propagation simulation is straightforward. In this case the submodel is created in a DBEM environment with boundary conditions provided by the global FEM analysis; then the crack is introduced and a crack propagation analysis has been performed to evaluate the effects of the crack shape and of the presence of nearby cracks on the allowed number of EM load cycles.

Keywords

Article history

  1. ReceivedUntil the next stage: 0 days
  2. AcceptedUntil the next stage: 0 days
  3. Published

How to cite

APA

Citarella, R., Lepore, M., Fellinger, J., Bykov, V., & Schauer, F. (2013). Coupled FEM-DBEM method to assess crack growth in magnet system of Wendelstein 7-X. Fracture and Structural Integrity, 7(26), Pages 92–103. https://doi.org/10.3221/IGF-ESIS.26.10

IEEE

R. Citarella, M. Lepore, J. Fellinger, V. Bykov, and F. Schauer, “Coupled FEM-DBEM method to assess crack growth in magnet system of Wendelstein 7-X,” Fracture and Structural Integrity, vol. 7, no. 26, pp. Pages 92–103, 2013, doi: 10.3221/IGF-ESIS.26.10.

MLA

Citarella, R., et al. “Coupled FEM-DBEM method to assess crack growth in magnet system of Wendelstein 7-X.” Fracture and Structural Integrity, vol. 7, no. 26, 2013, pp. Pages 92–103. https://doi.org/10.3221/IGF-ESIS.26.10.

Chicago

Citarella, R., M. Lepore, Joris Fellinger, Victor Bykov, and Felix Schauer. 2013. “Coupled FEM-DBEM method to assess crack growth in magnet system of Wendelstein 7-X.” Fracture and Structural Integrity 7 (26): Pages 92–103. https://doi.org/10.3221/IGF-ESIS.26.10.

Harvard

Citarella, R., Lepore, M., Fellinger, J., Bykov, V. and Schauer, F. (2013) ‘Coupled FEM-DBEM method to assess crack growth in magnet system of Wendelstein 7-X’, Fracture and Structural Integrity, 7(26), pp. Pages 92–103. doi: 10.3221/IGF-ESIS.26.10.

Vancouver

Citarella R, Lepore M, Fellinger J, Bykov V, Schauer F. Coupled FEM-DBEM method to assess crack growth in magnet system of Wendelstein 7-X. Fracture and Structural Integrity. 2013;7(26):Pages 92-103. doi:10.3221/IGF-ESIS.26.10

BibTeX

@article{citarella2013, author = {Citarella, R. and Lepore, M. and Fellinger, Joris and Bykov, Victor and Schauer, Felix}, title = {Coupled FEM-DBEM method to assess crack growth in magnet system of Wendelstein 7-X}, journal = {Fracture and Structural Integrity}, year = {2013}, volume = {7}, number = {26}, pages = {Pages 92--103}, doi = {10.3221/IGF-ESIS.26.10}, url = {https://doi.org/10.3221/IGF-ESIS.26.10}, issn = {1971-8993} }

RIS

TY - JOUR AU - Citarella, R. AU - Lepore, M. AU - Fellinger, Joris AU - Bykov, Victor AU - Schauer, Felix TI - Coupled FEM-DBEM method to assess crack growth in magnet system of Wendelstein 7-X JO - Fracture and Structural Integrity T2 - Fracture and Structural Integrity PY - 2013 DA - 2013/09/25 VL - 7 IS - 26 SP - Pages 92 EP - 103 DO - 10.3221/IGF-ESIS.26.10 UR - https://doi.org/10.3221/IGF-ESIS.26.10 SN - 1971-8993 ER -

Licence

Copyright © 2014 Fracture and Structural Integrity.

Copyright 
Authors are allowed to retain both the copyright and the publishing rights of their articles without restrictions.  

Open Access Statement

Fracture and Structural Integrity (F&SI) is an open-access journal which means that all content is freely available without charge to the user or his/her institution. Users are allowed to read, download, copy, distribute, print, search, or link to the full texts of the articles in this journal without asking prior permission from the publisher or the author. This is in accordance with the DOAI definition of open access.

F&SI operates under the Creative Commons Licence Attribution 4.0 International (CC-BY 4.0). This allows to copy and redistribute the material in any medium or format, to remix, transform and build upon the material for any purpose, even commercially, but giving appropriate credit, providing a link to the license, and indicating if changes were made.

Similar articles