Abstract

This study experimentally investigates the tensile and bond performance of novel GFRP–SSWM hybrid wraps developed using two epoxy adhesives - Sikadur 30 LP and Sikadur 330. A total of 42 coupon specimens for tensile testing and 48 dumbbell specimens for bond testing are prepared using various two-layer and three-layer configurations of GFRP, SSWM, and their hybrids. Tensile tests are conducted as per ASTM D3039, and specimen performance are evaluated in terms of ultimate load capacity, displacement at peak load, stiffness, rupture strain, and failure modes. Fractographic assessment is also performed at the failure plane of coupon specimens. Study results of tensile and bond test, indicate that GFRP-only specimens exhibit high tensile strength and stiffness but fail in a brittle manner, while SSWM-only specimens show greater ductility with reduced strength. Hybrid configurations offer a balanced response between strength and ductility. Among hybrids, GS specimens bonded with Sikadur 30 LP show superior performance in two-layer systems. Fractographic observations confirm effective hybrid action between GFRP and SSWM without delamination or layer separation at the interface. The capacity utilization ratio further supports that Sikadur 30 LP performs better than Sikadur 330, especially in hybrid configurations involving SSWM. The study highlights the mechanical viability of GFRP-SSWM hybrid wraps for use in strengthening applications.

Keywords

Article history

  1. ReceivedUntil the next stage: 20 days
  2. Revision requestedUntil the next stage: 16 days
  3. RevisedUntil the next stage: 7 days
  4. AcceptedUntil the next stage: 38 days
  5. Published

How to cite

APA

Kalyani, V., Joshi, D., & Patel, P. (2025). Experimental Investigation of Tensile and Bond Strength for a GFRP–SSWM Hybrid Wraps. Fracture and Structural Integrity, 19(74), 89–114. https://doi.org/10.3221/IGF-ESIS.74.07

IEEE

V. Kalyani, D. Joshi, and P. Patel, “Experimental Investigation of Tensile and Bond Strength for a GFRP–SSWM Hybrid Wraps,” Fracture and Structural Integrity, vol. 19, no. 74, pp. 89–114, 2025, doi: 10.3221/IGF-ESIS.74.07.

MLA

Kalyani, Vipul, et al. “Experimental Investigation of Tensile and Bond Strength for a GFRP–SSWM Hybrid Wraps.” Fracture and Structural Integrity, vol. 19, no. 74, 2025, pp. 89–114. https://doi.org/10.3221/IGF-ESIS.74.07.

Chicago

Kalyani, Vipul, Digesh Joshi, and Paresh Patel. 2025. “Experimental Investigation of Tensile and Bond Strength for a GFRP–SSWM Hybrid Wraps.” Fracture and Structural Integrity 19 (74): 89–114. https://doi.org/10.3221/IGF-ESIS.74.07.

Harvard

Kalyani, V., Joshi, D. and Patel, P. (2025) ‘Experimental Investigation of Tensile and Bond Strength for a GFRP–SSWM Hybrid Wraps’, Fracture and Structural Integrity, 19(74), pp. 89–114. doi: 10.3221/IGF-ESIS.74.07.

Vancouver

Kalyani V, Joshi D, Patel P. Experimental Investigation of Tensile and Bond Strength for a GFRP–SSWM Hybrid Wraps. Fracture and Structural Integrity. 2025;19(74):89-114. doi:10.3221/IGF-ESIS.74.07

BibTeX

@article{kalyani2025, author = {Kalyani, Vipul and Joshi, Digesh and Patel, Paresh}, title = {Experimental Investigation of Tensile and Bond Strength for a GFRP–SSWM Hybrid Wraps}, journal = {Fracture and Structural Integrity}, year = {2025}, volume = {19}, number = {74}, pages = {89--114}, doi = {10.3221/IGF-ESIS.74.07}, url = {https://doi.org/10.3221/IGF-ESIS.74.07}, issn = {1971-8993} }

RIS

TY - JOUR AU - Kalyani, Vipul AU - Joshi, Digesh AU - Patel, Paresh TI - Experimental Investigation of Tensile and Bond Strength for a GFRP–SSWM Hybrid Wraps JO - Fracture and Structural Integrity T2 - Fracture and Structural Integrity PY - 2025 DA - 2025/08/10 VL - 19 IS - 74 SP - 89 EP - 114 DO - 10.3221/IGF-ESIS.74.07 UR - https://doi.org/10.3221/IGF-ESIS.74.07 SN - 1971-8993 ER -

Licence

Creative Commons Attribution 4.0 International

May be shared and adapted, provided appropriate credit is given. Copyright © 2025 Vipul Kalyani, Digesh Joshi, Paresh Patel.

Copyright 
Authors are allowed to retain both the copyright and the publishing rights of their articles without restrictions.  

Open Access Statement

Fracture and Structural Integrity (F&SI) is an open-access journal which means that all content is freely available without charge to the user or his/her institution. Users are allowed to read, download, copy, distribute, print, search, or link to the full texts of the articles in this journal without asking prior permission from the publisher or the author. This is in accordance with the DOAI definition of open access.

F&SI operates under the Creative Commons Licence Attribution 4.0 International (CC-BY 4.0). This allows to copy and redistribute the material in any medium or format, to remix, transform and build upon the material for any purpose, even commercially, but giving appropriate credit, providing a link to the license, and indicating if changes were made.

Similar articles