Fracture and Structural Integrity e-ISSN 1971-8993 Open access
SI: Russian mechanics contributions for Structural Integrity Vol. 19, No. 72 (2025)

Application of perforated PEEK framework for improving strength of a bases of removable complete denture for maxilla

Author and affiliation details
  • Kamalutdin Akhmedov Russian University of Medicine, 127006, Moscow, Russia
  • Dmitry Arutyunov Russian University of Medicine, 127006, Moscow, Russia
  • Mikhail Lomakin Russian University of Medicine, 127006, Moscow, Russia
  • Svetlana Bochkareva Institute of Strength Physics and Materials Science of the Siberian Branch of the Russian Academy of Sciences (ISPMS SB RAS), 634055, Tomsk, Russia ORCID iD0000-0003-4889-6128
  • Iliya Panov Institute of Strength Physics and Materials Science of the Siberian Branch of the Russian Academy of Sciences (ISPMS SB RAS), 634055, Tomsk, Russia ORCID iD0000-0001-6214-5633
  • Sergey Panin Corresponding author Institute of Strength Physics and Materials Science of the Siberian Branch of the Russian Academy of Sciences (ISPMS SB RAS), 634055, Tomsk, Russia ORCID iD0000-0001-7623-7360 paninsergey71@mail.ru
  • Magomet Mustafaev Kabardino-Balkarian State University, 360004, Nalchik, Russia
  • Sofiat Mustafaeva Kabardino-Balkarian State University, 360004, Nalchik, Russia
DOI
10.3221/IGF-ESIS.72.20
Pages
280-294
Published
Licence
CC BY 4.0

Abstract

The paper presents the results of computer simulation of a hybrid removable complete dentures (RCD) of a maxilla and analysis of its stress–strain states (SSSs) under typical operational loads. For improving their strength and stiffness, it was proposed to reinforce a base made of polymethylmethacrylate (PMMA) with a perforated framework (technological holes for enhancing adhesion) made of polyetheretherketone (PEEK). In total, the SSS for 10 different models were analyzed, simulating the presence or absence of a reinforcing framework as well as its perforation, location in the base, adhesion between the components, and the deformation of the alveolar ridge. The key difference of the conducted computer simulation was the application of a virtual support of the RCD. Its deformation imitated changes in the alveolar ridge height, as well as the presence of more rigid areas corresponding directly to both alveolar ridge and a torus. The SSSs for the FE-models were calculated by the finite element method using the ‘ABAQUS’ software package. The effect of the PEEK framework position on the mechanical properties of the RСD was assessed. It was shown that the main reason for the base’s failure was its bending under the applied loads. However, the load-bearing capacity of the RСD could be increased by 20–40% by embedding of the PEEK framework as an additional layer of the base dome. The effect of variation in the base support conditions, simulating the degradation of the alveolar ridge caused by the bone tissue resorption, was analyzed. It was found that the load-bearing capacity of the RСD could vary within 10% in such cases. The perforation in the PEEK framework did not reduce significantly the mechanical properties of the RСD, but its adhesion to the PMMA base exerted a decisive effect on the operational performance.

Keywords

Article history

  1. ReceivedUntil the next stage: 30 days
  2. Revision requestedUntil the next stage: 12 days
  3. RevisedUntil the next stage: 1 day
  4. AcceptedUntil the next stage: 4 days
  5. Published

How to cite

APA

Akhmedov, K., Arutyunov, D., Lomakin, M., Bochkareva, S., Panov, I., Panin, S., Mustafaev, M., & Mustafaeva, S. (2025). Application of perforated PEEK framework for improving strength of a bases of removable complete denture for maxilla. Fracture and Structural Integrity, 19(72), 280–294. https://doi.org/10.3221/IGF-ESIS.72.20

IEEE

K. Akhmedov et al., “Application of perforated PEEK framework for improving strength of a bases of removable complete denture for maxilla,” Fracture and Structural Integrity, vol. 19, no. 72, pp. 280–294, 2025, doi: 10.3221/IGF-ESIS.72.20.

MLA

Akhmedov, Kamalutdin, et al. “Application of perforated PEEK framework for improving strength of a bases of removable complete denture for maxilla.” Fracture and Structural Integrity, vol. 19, no. 72, 2025, pp. 280–294. https://doi.org/10.3221/IGF-ESIS.72.20.

Chicago

Akhmedov, Kamalutdin, Dmitry Arutyunov, Mikhail Lomakin, Svetlana Bochkareva, Iliya Panov, Sergey Panin, Magomet Mustafaev, and Sofiat Mustafaeva. 2025. “Application of perforated PEEK framework for improving strength of a bases of removable complete denture for maxilla.” Fracture and Structural Integrity 19 (72): 280–294. https://doi.org/10.3221/IGF-ESIS.72.20.

Harvard

Akhmedov, K., Arutyunov, D., Lomakin, M., Bochkareva, S., Panov, I., Panin, S., Mustafaev, M. and Mustafaeva, S. (2025) ‘Application of perforated PEEK framework for improving strength of a bases of removable complete denture for maxilla’, Fracture and Structural Integrity, 19(72), pp. 280–294. doi: 10.3221/IGF-ESIS.72.20.

Vancouver

Akhmedov K, Arutyunov D, Lomakin M, Bochkareva S, Panov I, Panin S, et al. Application of perforated PEEK framework for improving strength of a bases of removable complete denture for maxilla. Fracture and Structural Integrity. 2025;19(72):280-294. doi:10.3221/IGF-ESIS.72.20

BibTeX

@article{akhmedov2025, author = {Akhmedov, Kamalutdin and Arutyunov, Dmitry and Lomakin, Mikhail and Bochkareva, Svetlana and Panov, Iliya and Panin, Sergey and Mustafaev, Magomet and Mustafaeva, Sofiat}, title = {Application of perforated PEEK framework for improving strength of a bases of removable complete denture for maxilla}, journal = {Fracture and Structural Integrity}, year = {2025}, volume = {19}, number = {72}, pages = {280--294}, doi = {10.3221/IGF-ESIS.72.20}, url = {https://doi.org/10.3221/IGF-ESIS.72.20}, issn = {1971-8993} }

RIS

TY - JOUR AU - Akhmedov, Kamalutdin AU - Arutyunov, Dmitry AU - Lomakin, Mikhail AU - Bochkareva, Svetlana AU - Panov, Iliya AU - Panin, Sergey AU - Mustafaev, Magomet AU - Mustafaeva, Sofiat TI - Application of perforated PEEK framework for improving strength of a bases of removable complete denture for maxilla JO - Fracture and Structural Integrity T2 - Fracture and Structural Integrity PY - 2025 DA - 2025/03/26 VL - 19 IS - 72 SP - 280 EP - 294 DO - 10.3221/IGF-ESIS.72.20 UR - https://doi.org/10.3221/IGF-ESIS.72.20 SN - 1971-8993 ER -

Licence

Creative Commons Attribution 4.0 International

May be shared and adapted, provided appropriate credit is given. Copyright © 2025 Kamalutdin Akhmedov, Dmitry Arutyunov, Mikhail Lomakin, Svetlana Bochkareva, Iliya Panov, Sergey Panin, Magomet Mustafaev, Sofiat Mustafaeva.

Copyright 
Authors are allowed to retain both the copyright and the publishing rights of their articles without restrictions.  

Open Access Statement

Fracture and Structural Integrity (F&SI) is an open-access journal which means that all content is freely available without charge to the user or his/her institution. Users are allowed to read, download, copy, distribute, print, search, or link to the full texts of the articles in this journal without asking prior permission from the publisher or the author. This is in accordance with the DOAI definition of open access.

F&SI operates under the Creative Commons Licence Attribution 4.0 International (CC-BY 4.0). This allows to copy and redistribute the material in any medium or format, to remix, transform and build upon the material for any purpose, even commercially, but giving appropriate credit, providing a link to the license, and indicating if changes were made.

Similar articles