Fracture and Structural Integrity e-ISSN 1971-8993 Open access
Fatigue and Fracture of metallic alloys Vol. 18, No. 68 (2024)

Ultrasonic fatigue testing of AISI 304 and 316 stainless steels under environmental and immersion conditions

Author and affiliation details
  • Luis M. Torres Duarte University of Michoacán (UMSNH), Faculty of Mechanical Engineering, Santiago Tapia 403, Col. Centro, Morelia, 58000, Mexico
  • Gonzalo Mariano Domínguez Almaraz Corresponding author University of Michoacán (UMSNH), Faculty of Mechanical Engineering, Santiago Tapia 403, Col. Centro, Morelia, 58000, Mexico ORCID iD0000-0002-8786-8640 dalmaraz@umich.mx
  • Hipólito M. Venegas Montaño University of Michoacán (UMSNH), Faculty of Mechanical Engineering, Santiago Tapia 403, Col. Centro, Morelia, 58000, Mexico
DOI
10.3221/IGF-ESIS.68.11
Pages
175-185
Published
Licence
CC BY 4.0

Abstract

Ultrasonic fatigue tests were carried out on stainless steel AISI 316 and 304, under two modalities: at room temperature and in immersion (water for 316 and antifreeze for 304 steels); all tests were carried out with a loading ratio R=-1. The results obtained in the tests at room temperature (without immersion), for both materials exhibited a significant increase in temperature, leaving heat marks on the narrow section of the specimens. This phenomenon occurred due to the low coefficient of thermal conductivity of these stainless steels (16.2 W/ (m °K)), and the recorded temperatures were around 200 °C, generating instantaneous failure of material. Analyzes of fracture surfaces on specimens tested at room temperature reveal that crack initiation was related to the high temperature, causing alteration at the granular scale of the material, followed by a typical behavior crack propagation and failure. For specimens tested under immersion conditions, it was possible to reduce the temperature below 100 °C, which solved the problem of failure due to thermal effect. The results for 316 stainless steel immersed in water showed a fatigue life of 1.188×1010 cycles at188 MPa of stress loading in the specimen; while specimens subjected to 263 MPa stress showed a fatigue life of around 7×106 cycles, representing a significant reduction with an approximate factor of 1700. On the other hand, specimens of 304 stainless steel immersed in antifreeze with the lowest loading values of 169 MPa, showing an infinite ultrasonic fatigue life; while tests subjected to 263 MPa loading stress attains 3.62×106 cycles of ultrasonic fatigue life. The scanning electron microscopy visualizations for both cases of immersion tests showed that the initiation and propagation of the crack occurred on the surface of the specimens, exhibiting the typical mechanical fracture behavior without any apparent thermal influence.

Keywords

Article history

  1. ReceivedUntil the next stage: 65 days
  2. RevisedUntil the next stage: 4 days
  3. AcceptedUntil the next stage: 41 days
  4. Published

How to cite

APA

Torres Duarte, L. M., Domínguez Almaraz, G. M., & Venegas Montaño, H. M. (2024). Ultrasonic fatigue testing of AISI 304 and 316 stainless steels under environmental and immersion conditions. Fracture and Structural Integrity, 18(68), 175–185. https://doi.org/10.3221/IGF-ESIS.68.11

IEEE

L. M. Torres Duarte, G. M. Domínguez Almaraz, and H. M. Venegas Montaño, “Ultrasonic fatigue testing of AISI 304 and 316 stainless steels under environmental and immersion conditions,” Fracture and Structural Integrity, vol. 18, no. 68, pp. 175–185, 2024, doi: 10.3221/IGF-ESIS.68.11.

MLA

Torres Duarte, Luis M., et al. “Ultrasonic fatigue testing of AISI 304 and 316 stainless steels under environmental and immersion conditions.” Fracture and Structural Integrity, vol. 18, no. 68, 2024, pp. 175–185. https://doi.org/10.3221/IGF-ESIS.68.11.

Chicago

Torres Duarte, Luis M., Gonzalo Mariano Domínguez Almaraz, and Hipólito M. Venegas Montaño. 2024. “Ultrasonic fatigue testing of AISI 304 and 316 stainless steels under environmental and immersion conditions.” Fracture and Structural Integrity 18 (68): 175–185. https://doi.org/10.3221/IGF-ESIS.68.11.

Harvard

Torres Duarte, L.M., Domínguez Almaraz, G.M. and Venegas Montaño, H.M. (2024) ‘Ultrasonic fatigue testing of AISI 304 and 316 stainless steels under environmental and immersion conditions’, Fracture and Structural Integrity, 18(68), pp. 175–185. doi: 10.3221/IGF-ESIS.68.11.

Vancouver

Torres Duarte LM, Domínguez Almaraz GM, Venegas Montaño HM. Ultrasonic fatigue testing of AISI 304 and 316 stainless steels under environmental and immersion conditions. Fracture and Structural Integrity. 2024;18(68):175-185. doi:10.3221/IGF-ESIS.68.11

BibTeX

@article{torresduarte2024, author = {Torres Duarte, Luis M. and Domínguez Almaraz, Gonzalo Mariano and Venegas Montaño, Hipólito M.}, title = {Ultrasonic fatigue testing of AISI 304 and 316 stainless steels under environmental and immersion conditions}, journal = {Fracture and Structural Integrity}, year = {2024}, volume = {18}, number = {68}, pages = {175--185}, doi = {10.3221/IGF-ESIS.68.11}, url = {https://doi.org/10.3221/IGF-ESIS.68.11}, issn = {1971-8993} }

RIS

TY - JOUR AU - Torres Duarte, Luis M. AU - Domínguez Almaraz, Gonzalo Mariano AU - Venegas Montaño, Hipólito M. TI - Ultrasonic fatigue testing of AISI 304 and 316 stainless steels under environmental and immersion conditions JO - Fracture and Structural Integrity T2 - Fracture and Structural Integrity PY - 2024 DA - 2024/02/15 VL - 18 IS - 68 SP - 175 EP - 185 DO - 10.3221/IGF-ESIS.68.11 UR - https://doi.org/10.3221/IGF-ESIS.68.11 SN - 1971-8993 ER -

Licence

Creative Commons Attribution 4.0 International

May be shared and adapted, provided appropriate credit is given. Copyright © 2024 Luis M. Torres Duarte, Gonzalo Mariano Domínguez Almaraz, Hipólito M. Venegas Montaño.

Copyright 
Authors are allowed to retain both the copyright and the publishing rights of their articles without restrictions.  

Open Access Statement

Fracture and Structural Integrity (F&SI) is an open-access journal which means that all content is freely available without charge to the user or his/her institution. Users are allowed to read, download, copy, distribute, print, search, or link to the full texts of the articles in this journal without asking prior permission from the publisher or the author. This is in accordance with the DOAI definition of open access.

F&SI operates under the Creative Commons Licence Attribution 4.0 International (CC-BY 4.0). This allows to copy and redistribute the material in any medium or format, to remix, transform and build upon the material for any purpose, even commercially, but giving appropriate credit, providing a link to the license, and indicating if changes were made.

Similar articles

Most read articles by the same author(s)