Fracture and Structural Integrity e-ISSN 1971-8993 Open access
Analytical, Numerical and Physical Models Vol. 15, No. 56 (2021)

Effect of multi-layer prosthetic foam liner on the stresses at the stump–prosthetic interface

Author and affiliation details
  • Ismail Boudjemaa Corresponding author Department of Mechanical Engineering, Laboratory Mechanics Physics of Materials (LMPM), University of SidiBel Abbes, BP 89, cite Ben M’hidi, SidiBel Abbes, 22000, Algeria ismailboubou000@gmail.com
  • Abderahmane Sahli Department of Mechanical Engineering, Laboratory Mechanics Physics of Materials (LMPM), University of SidiBel Abbes, BP 89, cite Ben M’hidi, SidiBel Abbes, 22000, Algeria ORCID iD0000-0002-5183-1168
  • Abdelkader Benkhettou Department of Mechanical Engineering, Laboratory Mechanics Physics of Materials (LMPM), University of SidiBel Abbes, BP 89, cite Ben M’hidi, SidiBel Abbes, 22000, Algeria
  • Smail Benbarek Department of Mechanical Engineering, Laboratory Mechanics Physics of Materials (LMPM), University of SidiBel Abbes, BP 89, cite Ben M’hidi, SidiBel Abbes, 22000, Algeria
DOI
10.3221/IGF-ESIS.56.15
Pages
187-194
Published
Licence
CC BY 4.0

Abstract

The prosthetic liner plays a significant role in the redistribution of the pressure between the stump and the socket, as it adding a cushioning layer between the stump and the socket which relieves pain and makes the prosthesis more comfortable.

This study employed nonlinear finite element analyses to investigate the peak pressure and shear stress at stump–prosthetic interface in the case of multi-layer prosthetic foam liner, this liner having an inner polymeric foam layer Surrounded by another type of polymeric foam layer, we used three different types of foams in different order to define this liner (flexible polyurethane foam, polyurethane-shape memory polymer foam, and natural rubber latex foam). That’s allows comparing 6 deferent configuration of multi-layer prosthetic foam liner.      

Keywords

Article history

  1. ReceivedUntil the next stage: 21 days
  2. RevisedUntil the next stage: 0 days
  3. AcceptedUntil the next stage: 10 days
  4. Published

How to cite

APA

Boudjemaa, I., Sahli, A., Benkhettou, A., & Benbarek, S. (2021). Effect of multi-layer prosthetic foam liner on the stresses at the stump–prosthetic interface. Fracture and Structural Integrity, 15(56), 187–194. https://doi.org/10.3221/IGF-ESIS.56.15

IEEE

I. Boudjemaa, A. Sahli, A. Benkhettou, and S. Benbarek, “Effect of multi-layer prosthetic foam liner on the stresses at the stump–prosthetic interface,” Fracture and Structural Integrity, vol. 15, no. 56, pp. 187–194, 2021, doi: 10.3221/IGF-ESIS.56.15.

MLA

Boudjemaa, Ismail, et al. “Effect of multi-layer prosthetic foam liner on the stresses at the stump–prosthetic interface.” Fracture and Structural Integrity, vol. 15, no. 56, 2021, pp. 187–194. https://doi.org/10.3221/IGF-ESIS.56.15.

Chicago

Boudjemaa, Ismail, Abderahmane Sahli, Abdelkader Benkhettou, and Smail Benbarek. 2021. “Effect of multi-layer prosthetic foam liner on the stresses at the stump–prosthetic interface.” Fracture and Structural Integrity 15 (56): 187–194. https://doi.org/10.3221/IGF-ESIS.56.15.

Harvard

Boudjemaa, I., Sahli, A., Benkhettou, A. and Benbarek, S. (2021) ‘Effect of multi-layer prosthetic foam liner on the stresses at the stump–prosthetic interface’, Fracture and Structural Integrity, 15(56), pp. 187–194. doi: 10.3221/IGF-ESIS.56.15.

Vancouver

Boudjemaa I, Sahli A, Benkhettou A, Benbarek S. Effect of multi-layer prosthetic foam liner on the stresses at the stump–prosthetic interface. Fracture and Structural Integrity. 2021;15(56):187-194. doi:10.3221/IGF-ESIS.56.15

BibTeX

@article{boudjemaa2021, author = {Boudjemaa, Ismail and Sahli, Abderahmane and Benkhettou, Abdelkader and Benbarek, Smail}, title = {Effect of multi-layer prosthetic foam liner on the stresses at the stump–prosthetic interface}, journal = {Fracture and Structural Integrity}, year = {2021}, volume = {15}, number = {56}, pages = {187--194}, doi = {10.3221/IGF-ESIS.56.15}, url = {https://doi.org/10.3221/IGF-ESIS.56.15}, issn = {1971-8993} }

RIS

TY - JOUR AU - Boudjemaa, Ismail AU - Sahli, Abderahmane AU - Benkhettou, Abdelkader AU - Benbarek, Smail TI - Effect of multi-layer prosthetic foam liner on the stresses at the stump–prosthetic interface JO - Fracture and Structural Integrity T2 - Fracture and Structural Integrity PY - 2021 DA - 2021/03/28 VL - 15 IS - 56 SP - 187 EP - 194 DO - 10.3221/IGF-ESIS.56.15 UR - https://doi.org/10.3221/IGF-ESIS.56.15 SN - 1971-8993 ER -

Licence

Creative Commons Attribution 4.0 International

May be shared and adapted, provided appropriate credit is given. Copyright © 2021 Ismail Boudjemaa, Abderahmane Sahli, Abdelkader Benkhettou, Smail Benbarek.

Copyright 
Authors are allowed to retain both the copyright and the publishing rights of their articles without restrictions.  

Open Access Statement

Fracture and Structural Integrity (F&SI) is an open-access journal which means that all content is freely available without charge to the user or his/her institution. Users are allowed to read, download, copy, distribute, print, search, or link to the full texts of the articles in this journal without asking prior permission from the publisher or the author. This is in accordance with the DOAI definition of open access.

F&SI operates under the Creative Commons Licence Attribution 4.0 International (CC-BY 4.0). This allows to copy and redistribute the material in any medium or format, to remix, transform and build upon the material for any purpose, even commercially, but giving appropriate credit, providing a link to the license, and indicating if changes were made.

Similar articles