Fracture and Structural Integrity e-ISSN 1971-8993 Open access
Structural Integrity and Durability of Structures Vol. 14, No. 53 (2020)

Monitoring and analysis of reinforced concrete plate-column structure under room temperature and fire based on acoustic emission

Author and affiliation details
  • Dongye Wang Huaqiao University, Xiamen 361021, China; Xiamen City University, Xiamen 361008, China
  • Yuli Dong Corresponding author Huaqiao University, Xiamen 361021, China dongyl@hqu.edu.cn
  • Dashan Zhang Huaqiao University, Xiamen 361021, China
  • Weihua Wang Huaqiao University, Xiamen 361021, China
  • Xin Lu Huaqiao University, Xiamen 361021, China
DOI
10.3221/IGF-ESIS.53.20
Pages
236-251
Published
Licence
CC BY 4.0

Abstract

This paper attempts to disclose the damage mechanism of reinforced concrete plate-column structure under room temperature and fire. Several tests were carried out to record the law of crack development on the plate surface under room temperature. The infrared detection technology was adopted to observe how cracks develop under fire. The acoustic emission (AE) signals at different positions of the specimen were monitored by the AE techniques. Coupled with the macroscopic test phenomena, several characteristic parameters collected by the AE system, namely, cumulative number of events, event rate, energy rate and b-value, were analyzed in details. The results show that: the cumulative number of events was active in the loading, heating and cooling stages; the crack density and the change of internal forces could be derived from the trend of event rate; the local energy changes of the specimen could be deciphered from the curves of energy rate and b-value, making it possible to judge if a component has reached the failure state; the specimen suffered the most severe damages, when the AE parameters suddenly changed; AE monitoring enables the early warning of fire to reinforced concrete plate-column structure; infrared detection technology is suitable for real-time monitoring of crack development under high temperature.

      

Keywords

Article history

  1. ReceivedUntil the next stage: 26 days
  2. Revision requestedUntil the next stage: 48 days
  3. RevisedUntil the next stage: 1 day
  4. AcceptedUntil the next stage: 70 days
  5. Published

How to cite

APA

Wang, D., Dong, Y., Zhang, D., Wang, W., & Lu, X. (2020). Monitoring and analysis of reinforced concrete plate-column structure under room temperature and fire based on acoustic emission. Fracture and Structural Integrity, 14(53), 236–251. https://doi.org/10.3221/IGF-ESIS.53.20

IEEE

D. Wang, Y. Dong, D. Zhang, W. Wang, and X. Lu, “Monitoring and analysis of reinforced concrete plate-column structure under room temperature and fire based on acoustic emission,” Fracture and Structural Integrity, vol. 14, no. 53, pp. 236–251, 2020, doi: 10.3221/IGF-ESIS.53.20.

MLA

Wang, Dongye, et al. “Monitoring and analysis of reinforced concrete plate-column structure under room temperature and fire based on acoustic emission.” Fracture and Structural Integrity, vol. 14, no. 53, 2020, pp. 236–251. https://doi.org/10.3221/IGF-ESIS.53.20.

Chicago

Wang, Dongye, Yuli Dong, Dashan Zhang, Weihua Wang, and Xin Lu. 2020. “Monitoring and analysis of reinforced concrete plate-column structure under room temperature and fire based on acoustic emission.” Fracture and Structural Integrity 14 (53): 236–251. https://doi.org/10.3221/IGF-ESIS.53.20.

Harvard

Wang, D., Dong, Y., Zhang, D., Wang, W. and Lu, X. (2020) ‘Monitoring and analysis of reinforced concrete plate-column structure under room temperature and fire based on acoustic emission’, Fracture and Structural Integrity, 14(53), pp. 236–251. doi: 10.3221/IGF-ESIS.53.20.

Vancouver

Wang D, Dong Y, Zhang D, Wang W, Lu X. Monitoring and analysis of reinforced concrete plate-column structure under room temperature and fire based on acoustic emission. Fracture and Structural Integrity. 2020;14(53):236-251. doi:10.3221/IGF-ESIS.53.20

BibTeX

@article{wang2020, author = {Wang, Dongye and Dong, Yuli and Zhang, Dashan and Wang, Weihua and Lu, Xin}, title = {Monitoring and analysis of reinforced concrete plate-column structure under room temperature and fire based on acoustic emission}, journal = {Fracture and Structural Integrity}, year = {2020}, volume = {14}, number = {53}, pages = {236--251}, doi = {10.3221/IGF-ESIS.53.20}, url = {https://doi.org/10.3221/IGF-ESIS.53.20}, issn = {1971-8993} }

RIS

TY - JOUR AU - Wang, Dongye AU - Dong, Yuli AU - Zhang, Dashan AU - Wang, Weihua AU - Lu, Xin TI - Monitoring and analysis of reinforced concrete plate-column structure under room temperature and fire based on acoustic emission JO - Fracture and Structural Integrity T2 - Fracture and Structural Integrity PY - 2020 DA - 2020/07/19 VL - 14 IS - 53 SP - 236 EP - 251 DO - 10.3221/IGF-ESIS.53.20 UR - https://doi.org/10.3221/IGF-ESIS.53.20 SN - 1971-8993 ER -

Licence

Creative Commons Attribution 4.0 International

May be shared and adapted, provided appropriate credit is given. Copyright © 2020 Yuli Dong, Dongye Wang, Dashan Zhang, Weihua Wang, Xin Lu.

Copyright 
Authors are allowed to retain both the copyright and the publishing rights of their articles without restrictions.  

Open Access Statement

Fracture and Structural Integrity (F&SI) is an open-access journal which means that all content is freely available without charge to the user or his/her institution. Users are allowed to read, download, copy, distribute, print, search, or link to the full texts of the articles in this journal without asking prior permission from the publisher or the author. This is in accordance with the DOAI definition of open access.

F&SI operates under the Creative Commons Licence Attribution 4.0 International (CC-BY 4.0). This allows to copy and redistribute the material in any medium or format, to remix, transform and build upon the material for any purpose, even commercially, but giving appropriate credit, providing a link to the license, and indicating if changes were made.