Fracture and Structural Integrity e-ISSN 1971-8993 Open access
Miscellanea Vol. 7, No. 23 (2013)

Functional fatigue of NiTi Shape Memory wires for a range of end loadings and constraints

Author and affiliation details
  • G. Scirè Mammano Corresponding author Department of Engineering Sciences and Methods, University of Modena and Reggio Emilia – Reggio Emilia – Italy giovanni.sciremammano@unimore.it
  • E. Dragoni Department of Engineering Sciences and Methods, University of Modena and Reggio Emilia – Reggio Emilia – Italy
DOI
10.3221/IGF-ESIS.23.03
Pages
Pages 14-33
Published

Abstract

The availability of engineering strength data on shape memory alloys (SMAs) under cyclic thermal activation (functional fatigue) is central to the rational design of smart actuators based on these materials. Test results on SMAs under functional fatigue are scarce in the technical literature and the few data available are mainly limited to constant-stress loading. Since the SMA elements used within actuators are normally biased by elastic springs or by another SMA element, their stress state is far from constant in operation. The mismatch between actual working conditions and laboratory arrangements leads to suboptimal designs and undermines the prediction of the actuator lifetime. This paper aims at bridging the gap between experiment and reality. Four test procedures are planned, covering most of the typical situations occurring in practice: constant-stress, constant-strain, constant-stress with limited maximum strain and linear stress-strain variation with limited maximum strain. The paper describes the experimental apparatus specifically designed to implement the four loading conditions and presents fatigue results obtained from commercial NiTi wires tested under all those protocols.

Keywords

Article history

  1. ReceivedUntil the next stage: 0 days
  2. AcceptedUntil the next stage: 0 days
  3. Published

How to cite

APA

Mammano, G. S., & Dragoni, E. (2012). Functional fatigue of NiTi Shape Memory wires for a range of end loadings and constraints. Fracture and Structural Integrity, 7(23), Pages 14–33. https://doi.org/10.3221/IGF-ESIS.23.03

IEEE

G. S. Mammano and E. Dragoni, “Functional fatigue of NiTi Shape Memory wires for a range of end loadings and constraints,” Fracture and Structural Integrity, vol. 7, no. 23, pp. Pages 14–33, 2012, doi: 10.3221/IGF-ESIS.23.03.

MLA

Mammano, G. Scirè, and E. Dragoni. “Functional fatigue of NiTi Shape Memory wires for a range of end loadings and constraints.” Fracture and Structural Integrity, vol. 7, no. 23, 2012, pp. Pages 14–33. https://doi.org/10.3221/IGF-ESIS.23.03.

Chicago

Mammano, G. Scirè, and E. Dragoni. 2012. “Functional fatigue of NiTi Shape Memory wires for a range of end loadings and constraints.” Fracture and Structural Integrity 7 (23): Pages 14–33. https://doi.org/10.3221/IGF-ESIS.23.03.

Harvard

Mammano, G.S. and Dragoni, E. (2012) ‘Functional fatigue of NiTi Shape Memory wires for a range of end loadings and constraints’, Fracture and Structural Integrity, 7(23), pp. Pages 14–33. doi: 10.3221/IGF-ESIS.23.03.

Vancouver

Mammano GS, Dragoni E. Functional fatigue of NiTi Shape Memory wires for a range of end loadings and constraints. Fracture and Structural Integrity. 2012;7(23):Pages 14-33. doi:10.3221/IGF-ESIS.23.03

BibTeX

@article{mammano2012, author = {Mammano, G. Scirè and Dragoni, E.}, title = {Functional fatigue of NiTi Shape Memory wires for a range of end loadings and constraints}, journal = {Fracture and Structural Integrity}, year = {2012}, volume = {7}, number = {23}, pages = {Pages 14--33}, doi = {10.3221/IGF-ESIS.23.03}, url = {https://doi.org/10.3221/IGF-ESIS.23.03}, issn = {1971-8993} }

RIS

TY - JOUR AU - Mammano, G. Scirè AU - Dragoni, E. TI - Functional fatigue of NiTi Shape Memory wires for a range of end loadings and constraints JO - Fracture and Structural Integrity T2 - Fracture and Structural Integrity PY - 2012 DA - 2012/12/28 VL - 7 IS - 23 SP - Pages 14 EP - 33 DO - 10.3221/IGF-ESIS.23.03 UR - https://doi.org/10.3221/IGF-ESIS.23.03 SN - 1971-8993 ER -

Licence

Copyright © 2014 Fracture and Structural Integrity.

Copyright 
Authors are allowed to retain both the copyright and the publishing rights of their articles without restrictions.  

Open Access Statement

Fracture and Structural Integrity (F&SI) is an open-access journal which means that all content is freely available without charge to the user or his/her institution. Users are allowed to read, download, copy, distribute, print, search, or link to the full texts of the articles in this journal without asking prior permission from the publisher or the author. This is in accordance with the DOAI definition of open access.

F&SI operates under the Creative Commons Licence Attribution 4.0 International (CC-BY 4.0). This allows to copy and redistribute the material in any medium or format, to remix, transform and build upon the material for any purpose, even commercially, but giving appropriate credit, providing a link to the license, and indicating if changes were made.

Similar articles