This paper examines leakage and damages of steam and provides an overview of NDT testing in order to determine the cause of steam lines failure in power plants and heating plants. This approach may be applied to similar structures and its application in preventive maintenance would help extend the life of steam pipes.
Bulatovic, S., Aleksic, V., & Milovic, L. (2013). Failure of steam line causes determined by NDT testing in power and heating plants. Fracture and Structural Integrity, 7(26), Pages 41–48. https://doi.org/10.3221/IGF-ESIS.26.05
IEEE
S. Bulatovic, V. Aleksic, and L. Milovic, “Failure of steam line causes determined by NDT testing in power and heating plants,” Fracture and Structural Integrity, vol. 7, no. 26, pp. Pages 41–48, 2013, doi: 10.3221/IGF-ESIS.26.05.
MLA
Bulatovic, Srdjan, et al. “Failure of steam line causes determined by NDT testing in power and heating plants.” Fracture and Structural Integrity, vol. 7, no. 26, 2013, pp. Pages 41–48. https://doi.org/10.3221/IGF-ESIS.26.05.
Chicago
Bulatovic, Srdjan, Vujadin Aleksic, and Ljubica Milovic. 2013. “Failure of steam line causes determined by NDT testing in power and heating plants.” Fracture and Structural Integrity 7 (26): Pages 41–48. https://doi.org/10.3221/IGF-ESIS.26.05.
Harvard
Bulatovic, S., Aleksic, V. and Milovic, L. (2013) ‘Failure of steam line causes determined by NDT testing in power and heating plants’, Fracture and Structural Integrity, 7(26), pp. Pages 41–48. doi: 10.3221/IGF-ESIS.26.05.
Vancouver
Bulatovic S, Aleksic V, Milovic L. Failure of steam line causes determined by NDT testing in power and heating plants. Fracture and Structural Integrity. 2013;7(26):Pages 41-48. doi:10.3221/IGF-ESIS.26.05
BibTeX
@article{bulatovic2013,
author = {Bulatovic, Srdjan and Aleksic, Vujadin and Milovic, Ljubica},
title = {Failure of steam line causes determined by NDT testing in power and heating plants},
journal = {Fracture and Structural Integrity},
year = {2013},
volume = {7},
number = {26},
pages = {Pages 41--48},
doi = {10.3221/IGF-ESIS.26.05},
url = {https://doi.org/10.3221/IGF-ESIS.26.05},
issn = {1971-8993}
}
RIS
TY - JOUR
AU - Bulatovic, Srdjan
AU - Aleksic, Vujadin
AU - Milovic, Ljubica
TI - Failure of steam line causes determined by NDT testing in power and heating plants
JO - Fracture and Structural Integrity
T2 - Fracture and Structural Integrity
PY - 2013
DA - 2013/09/25
VL - 7
IS - 26
SP - Pages 41
EP - 48
DO - 10.3221/IGF-ESIS.26.05
UR - https://doi.org/10.3221/IGF-ESIS.26.05
SN - 1971-8993
ER -
Copyright Authors are allowed to retain both the copyright and the publishing rights of their articles without restrictions.
Open Access Statement
Fracture and Structural Integrity (F&SI) is an open-access journal which means that all content is freely available without charge to the user or his/her institution. Users are allowed to read, download, copy, distribute, print, search, or link to the full texts of the articles in this journal without asking prior permission from the publisher or the author. This is in accordance with the DOAI definition of open access.
F&SI operates under the Creative Commons Licence Attribution 4.0 International (CC-BY 4.0). This allows to copy and redistribute the material in any medium or format, to remix, transform and build upon the material for any purpose, even commercially, but giving appropriate credit, providing a link to the license, and indicating if changes were made.